Choose the Atios SmartCore if you want a DIN-rail relay controller powered by its Ethernet cable. If you have AC power at the panel, choose the Shelly Pro 3 for dry contacts or the Shelly Pro 4PM V2 for metered AC outputs. Atios datasheet · Pro 3 specifications · Pro 4PM V2 specifications
Compare power, contacts and control
| Controller | Controller power for a wired setup | Relay outputs | Home Assistant integration |
|---|---|---|---|
| Atios SmartCore ADE-R12-2.0 | 802.3af PoE or external 20–30 V DC | 12 bistable dry contacts (16 A, 250 V AC) | Matter |
| Shelly Pro 3 | 110–240 V AC at the power terminals, with Ethernet for data | 3 dry contacts, with published switching limits of 16 A per channel and 48 A total | Shelly |
| Shelly Pro 4PM V2 | 110–240 V AC at the power terminals, with Ethernet for data | 4 metered AC outputs, with published switching limits of 16 A per channel and 40 A total | Shelly |
For PoE, plan two power paths. Run the Ethernet cable from an 802.3af PoE switch port to the SmartCore’s LAN port. Choose either PoE or the external DC input. The dry contacts switch power from the load supply. Atios datasheet · SmartCore wiring guide
For Ethernet with AC power, match the outputs to the job. The Pro 3 has separate load inputs and outputs for each of its three dry-contact relays. The Pro 4PM measures power and energy separately on each channel. Pro 3 specifications · Pro 4PM metering documentation
Before ordering, count your loads, match their voltage, current and load type to the model’s specifications, and check the mounting dimensions. The SmartCore takes up 10 DIN modules. Use the wiring instructions for your exact model. For DALI lighting on the SmartCore, use the separate commissioning guide. Atios datasheet · SmartCore wiring guide · Pro 3 specifications · Pro 4PM V2 specifications · DALI commissioning guide
Add an Atios relay to Home Assistant over Matter
For a non-lighting on/off load already connected to Output 01, map that output to a Switch accessory before pairing. Atios ships the SmartCore with each digital input mapped to the matching output, so check the existing mapping for your circuit. SmartCore quick start · Accessory Manager
- At
setup.atios.ch, select your SmartCore and click Connect. In Accessory Manager, select + and choose Switch. Give it a name, select Output 01, then click Save Configuration and reboot. SmartCore quick start · Accessory Manager - In System Settings, enable Matter and let the SmartCore reboot. The Matter pairing QR code is in System Settings. Atios pairing guide · SmartCore quick start
- On a regular Home Assistant OS setup that supports the official Matter Server app, open Settings > Devices & services and add Matter. Select Submit when prompted for the connection method to install the official Matter Server app. Home Assistant Matter integration
- For a new device, open the current Companion app on an iPhone running iOS 16 or later with Bluetooth enabled. Go to Settings > Connectivity > Matter, choose Add device, then No. It’s new. Scan the SmartCore QR code, tap Add to Home Assistant, and follow the prompts. Home Assistant Matter integration
Add either Shelly relay over Ethernet
Shelly requires the controller to be off when you connect or disconnect its LAN cable. Use a plug with nonmetallic surfaces wherever you touch it to plug or unplug the cable. Pro 3 specifications · Pro 4PM V2 specifications
- In Home Assistant, open Settings > Devices & services. Set up the Shelly if it appears under Discovered. Home Assistant Shelly integration
- To add it manually, select Add Integration > Shelly. Find the controller in your router and enter its hostname or IP address in Host, then follow the prompts. Home Assistant Shelly integration
The Shelly integration connects directly to the device and adds its relays as switch entities by default. Home Assistant Shelly integration
Evidence and limits. The Atios ADE-R12-2.0 datasheet, Shelly Pro 3 and Pro 4PM V2 references, Shelly Gen2 API documentation, and Home Assistant integration guides were checked on November 26, 2026. The setup steps were not run on hardware.